Jun 25,2026
Reasons for severe vibration of three-dimensional mixer
(1) The maintenance hammer component is installed incorrectly. The hammer changer is used to prevent the rotor weight from being out of balance, in a hammer mill all changes together face the rotating surface in reverse, otherwise strong vibrations would occur during operation.
(2) The difference in hammer weight corresponding to the two groups exceeds 500 grams. Excluded is adjusting the weight of the hammer so that the difference between the weights of the groups is less than 5 grams.
(3) Some hammers are stuck too tightly, do not let go. You can stop and observe the backward turning with your hands, and find ways to make the hammer rotate flexibly.
(4) The rotor is unbalanced by weight. At this time, it is necessary to carefully examine and adjust the balance, respectively.
(5) After the bending deformation of the shaft, the solution is straightened or replaced.