Reasons for severe vibration of three-dimensional mixer


(1) The maintenance hammer component is installed incorrectly. The hammer changer is used to prevent the rotor weight from being out of balance, in a hammer mill all changes together face the rotating surface in reverse, otherwise strong vibrations would occur during operation.

(2) The difference in hammer weight corresponding to the two groups exceeds 500 grams. Excluded is adjusting the weight of the hammer so that the difference between the weights of the groups is less than 5 grams.

(3) Some hammers are stuck too tightly, do not let go. You can stop and observe the backward turning with your hands, and find ways to make the hammer rotate flexibly.

(4) The rotor is unbalanced by weight. At this time, it is necessary to carefully examine and adjust the balance, respectively.

(5) After the bending deformation of the shaft, the solution is straightened or replaced.

+ More Blog

 Jul 28,2022

Precautions for choosing a wastewater evaporator

Fully automated equipment (also capable of semi-automatic operation) does not require dedicated supervision, is easy to operate, has good water quality treatment effect, and is clean without odor.

 Jan 10,2022

What problems do vacuum dryers encounter in daily operation?

The so-called vacuum drying refers to heating and drying the dried material under vacuum conditions. If a vacuum pump is used for air and moisture extraction, the drying speed is accelerated. If a condenser is used, the solvent in the material can be recovered through the condenser.

 Nov 12,2021

Common faults and solutions of fluidized bed dryer

The material enters the machine from the feed inlet, and under the action of vibration force, the material is thrown along the horizontal fluidized bed, continuously moving forward. The hot air passes through the fluidized bed and exchanges heat with the wet material.